D.sign – firing parameters, Ip s – Ivoclar Vivadent IPS d.SIGN User Manual
Page 49
49
d.SIGN –
Firing parameters
IP
S
Firing parameters for the 1st opaquer firing
(wash firing)
T
900°C
1652°F
B
403°C
757°F
S
6 min.
6 min.
t
80°C
144°F
H
1 min.
1 min.
V
1
450°C
842°F
V
2
899°C
1650°F
➚
Firing parameters for the 2
nd
opaquer firing
T
890°C
1634°F
B
403°C
757°F
S
6 min.
6 min.
t
80°C
144°F
H
1 min.
1 min.
V
1
450°C
842°F
V
2
889°C
1632°
➚
Firing parameters for the 1
st
shoulder firing
T
890°C
1634°F
B
403°C
757°F
S
6 min.
6 min.
t
60°C
108°F
H
1 min.
1 min.
V
1
450°C
842°F
V
2
889°C
1632°F
➚
Firing parameters for the 2
nd
shoulder firing
T
890°C
1634°F
B
403°C
757°F
S
6 min.
6 min.
t
60°C
108°F
H
1 min.
1 min.
V
1
450°C
842°F
V
2
889°C
1632°F
➚
Firing parameters for the 1
st
dentin and incisal firing
T
870°C
1598°F
B
403°C
757°F
S
4–9 min.
4–9 min.
t
60°C
108°F
H
1 min.
1 min.
V
1
450°C
842°F
V
2
869°C
1596°F
➚
Firing parameters for the 2
nd
dentin and incisal firing
T
870°C
1598°F
B
403°C
757°F
S
4–9 min.
4–9 min.
t
60°C
108°F
H
1 min.
1 min.
V
1
450°C
842°F
V
2
869°C
1596°F
➚
Firing parameters for the stain and
characterization firing
T
830°C
1526°F
B
403°C
757°F
S
4 min.
4 min.
t
60°C
108°F
H
1–2 min.
1–2 min.
V
1
450°C
842°F
V
2
829°C
1524°F
➚
Firing parameters for glaze firing without glazing
material
T
870°C
1598°F
B
403°C
757°F
S
4 min.
4 min.
t
60°C
108°F
H
0.5–1 min.
0.5–1 min.
V
1
450°C
842°F
V
2
869°C
1596°F
➚
Firing parameters for glaze firing with glazing material
T
830°C
1526°F
B
403°C
757°F
S
4 min.
4 min.
t
60°C
108°F
H
1–2 min.
1–2 min.
V
1
450°C
842°F
V
2
829°C
1524°F
➚
Firing parameters for corrective firing with IPS d.SIGN
Margin Add-on (1:1) (glaze firing without glazing material)
T
870°C
1598°F
B
403°C
757°F
S
4 min.
4 min.
t
60°C
108°F
H
0.5–1 min.
0.5–1 min
V
1
450°C
842°F
V
2
869°C
1596°F
➚
Firing parameters for corrective firing with IPS d.SIGN
Margin Add-on (alone) (glaze firing with glazing material)
T
830°C
1526°F
B
403°C
757°F
S
4 min.
4 min.
t
60°C
108°F
H
1–2 min.
1–2 min.
V
1
450°C
842°F
V
2
829°C
1524°F
➚
Firing parameters for the corrective firing with
IPS d.SIGN Add-on material (1:1)
T
810°C
1490°F
B
403°C
757°F
S
4 min.
4 min.
t
60°C
108°F
H
1 min.
1 min.
V
1
450°C
842°F
V
2
809°C
1488°F
➚
Firing parameters for the corrective firing with
IPS d.SIGN Add-on material (alone)
T
750°C
1382°F
B
403°C
757°F
S
4 min.
4 min.
t
60°C
108°F
H
1 min.
1 min.
V
1
450°C
842°F
V
2
749°C
1380°F
➚
These firing parameters are guidance values. They are
valid for the Programat furnaces from Ivoclar Vivadent.
Deviations (approx. +/- 10 °C/18 °F) may occur,
– depending on the furnace generation
– if ceramic furnaces from other manufacturers are used
– in case of regional differences in the power supply or if
several electrical devices are operatated on the same
circuit.
T
890°C
1634°F
B
403°C
757°F
S
6 min.
6 min.
t
80°C
144°F
H
1 min.
1 min.
V
1
450°C
842°F
V
2
889°C
1632°
➚
Firing parameters for the IPS d.SIGN Opaquer F