beautypg.com

D.sign – firing parameters, Ip s – Ivoclar Vivadent IPS d.SIGN User Manual

Page 49

background image

49

d.SIGN –

Firing parameters

IP

S

Firing parameters for the 1st opaquer firing
(wash firing)

T

900°C

1652°F

B

403°C

757°F

S

6 min.
6 min.

t

80°C

144°F

H

1 min.
1 min.

V

1

450°C

842°F

V

2

899°C

1650°F

Firing parameters for the 2

nd

opaquer firing

T

890°C

1634°F

B

403°C

757°F

S

6 min.
6 min.

t

80°C

144°F

H

1 min.
1 min.

V

1

450°C

842°F

V

2

889°C

1632°

Firing parameters for the 1

st

shoulder firing

T

890°C

1634°F

B

403°C

757°F

S

6 min.
6 min.

t

60°C

108°F

H

1 min.
1 min.

V

1

450°C

842°F

V

2

889°C

1632°F

Firing parameters for the 2

nd

shoulder firing

T

890°C

1634°F

B

403°C

757°F

S

6 min.
6 min.

t

60°C

108°F

H

1 min.
1 min.

V

1

450°C

842°F

V

2

889°C

1632°F

Firing parameters for the 1

st

dentin and incisal firing

T

870°C

1598°F

B

403°C

757°F

S

4–9 min.
4–9 min.

t

60°C

108°F

H

1 min.
1 min.

V

1

450°C

842°F

V

2

869°C

1596°F

Firing parameters for the 2

nd

dentin and incisal firing

T

870°C

1598°F

B

403°C

757°F

S

4–9 min.
4–9 min.

t

60°C

108°F

H

1 min.
1 min.

V

1

450°C

842°F

V

2

869°C

1596°F

Firing parameters for the stain and
characterization firing

T

830°C

1526°F

B

403°C

757°F

S

4 min.
4 min.

t

60°C

108°F

H

1–2 min.
1–2 min.

V

1

450°C

842°F

V

2

829°C

1524°F

Firing parameters for glaze firing without glazing
material

T

870°C

1598°F

B

403°C

757°F

S

4 min.
4 min.

t

60°C

108°F

H

0.5–1 min.
0.5–1 min.

V

1

450°C

842°F

V

2

869°C

1596°F

Firing parameters for glaze firing with glazing material

T

830°C

1526°F

B

403°C

757°F

S

4 min.
4 min.

t

60°C

108°F

H

1–2 min.
1–2 min.

V

1

450°C

842°F

V

2

829°C

1524°F

Firing parameters for corrective firing with IPS d.SIGN
Margin Add-on (1:1)
(glaze firing without glazing material)

T

870°C

1598°F

B

403°C

757°F

S

4 min.
4 min.

t

60°C

108°F

H

0.5–1 min.

0.5–1 min

V

1

450°C

842°F

V

2

869°C

1596°F

Firing parameters for corrective firing with IPS d.SIGN
Margin Add-on (alone)
(glaze firing with glazing material)

T

830°C

1526°F

B

403°C

757°F

S

4 min.
4 min.

t

60°C

108°F

H

1–2 min.
1–2 min.

V

1

450°C

842°F

V

2

829°C

1524°F

Firing parameters for the corrective firing with
IPS d.SIGN Add-on material (1:1)

T

810°C

1490°F

B

403°C

757°F

S

4 min.
4 min.

t

60°C

108°F

H

1 min.
1 min.

V

1

450°C

842°F

V

2

809°C

1488°F

Firing parameters for the corrective firing with
IPS d.SIGN Add-on material (alone)

T

750°C

1382°F

B

403°C

757°F

S

4 min.
4 min.

t

60°C

108°F

H

1 min.
1 min.

V

1

450°C

842°F

V

2

749°C

1380°F

These firing parameters are guidance values. They are
valid for the Programat furnaces from Ivoclar Vivadent.
Deviations (approx. +/- 10 °C/18 °F) may occur,
– depending on the furnace generation
– if ceramic furnaces from other manufacturers are used
– in case of regional differences in the power supply or if

several electrical devices are operatated on the same
circuit.

T

890°C

1634°F

B

403°C

757°F

S

6 min.
6 min.

t

80°C

144°F

H

1 min.
1 min.

V

1

450°C

842°F

V

2

889°C

1632°

Firing parameters for the IPS d.SIGN Opaquer F