Ivoclar Vivadent IPS d.SIGN User Manual
Page 35

35
Firing parameters for the 1
st
shoulder firing
T
890°C
1634°F
B
403°C
757°F
S
6 min.
6 min.
t
60°C
108°F
H
1 min.
1 min.
V
1
450°C
842°F
V
2
889°C
1632°F
➚
Important
If furnaces from other manufacturers are used,
these parameters have to be adjusted accordingly.
Apply IPS d.SIGN Margin material generously in the cervical area in the shape of a drop…
... and dry.
Carefully remove the framework with the applied and dried shoulder material from the die.
Fire the restoration using the firing parameters for the 1
st
shoulder firing.
Sinter shrinkage of the shoulder after the 1
st
shoulder firing.
Tip:
When designing a ceramic shoulder (particularly for
bridges), the Margin material may be applied higher up in
the proximal areas. This will reduce interdental shrinkage
during the subsequent dentin and incisal firings.
- 14K (2 pages)
- 24K (2 pages)
- BioUniversal KFG (2 pages)
- Callisto 86 (2 pages)
- Harmony KF (2 pages)
- Callisto 86 (2 pages)
- Capricorn 15 (2 pages)
- BioUniversal KFG (2 pages)
- BioUniversal KFG (2 pages)
- BioUniversal E (2 pages)
- BioUniversal PdF (2 pages)
- Brite Gold (2 pages)
- Capricorn 15 (2 pages)
- Callisto Implant 33 (2 pages)
- Capricorn (2 pages)
- Colado CC (2 pages)
- Callisto 84 (2 pages)
- Callisto CP+ (2 pages)
- Callisto CPG (2 pages)
- Callisto Implant 60 (2 pages)
- CosmoPost (24 pages)
- Colado NC (2 pages)
- Elektra (2 pages)
- Evolution Lite (2 pages)
- ESPRIT (1 page)
- Elektra 10 (2 pages)
- IPS d.SIGN Ultra (2 pages)
- EP 5000 (1 page)
- Harmony 2 (2 pages)
- EP 600 (36 pages)
- Harmony Hard (2 pages)
- Harmony Medium (2 pages)
- Harmony Soft (2 pages)
- Heliobond (36 pages)
- Harmony 3 (2 pages)
- Harmony C&B 55 (2 pages)
- EP 600 Combi (40 pages)
- Harmony PF (2 pages)
- Harmony X-Hard (2 pages)
- IPS AcrylCAD (2 pages)
- IPS d.SIGN 30 (2 pages)
- IPS Classic (24 pages)
- IPS d.SIGN 59 (2 pages)
- IPS d.SIGN 84 (2 pages)
- IPS d.SIGN 96 (2 pages)