9
D, Mount back the pin and the butterfly-shape screw onto the pressing tool. Put the pressing tool on
right position and close the handles to finish the pressing procedure.
E, Release and remove the butterfly-shape screw and the pin from the pressing tool, if necessary take
off the lengthened handles,then open the jaws and move the pressing jaws away from the pressed
fitting without opening the handles or lengthened handles.
G, Mount back the pin and the butterfly-shape screw onto the pressing tool. The pressing at corner or
narrow space is then completed.
6, Pressing F5 (U-profile) fittings with the pressing tool
A, When pressing F5 series fittings, place the jaw's end align with the press sleeve’s end which is by
the plastic ring, close the pressing tool completely.