beautypg.com

Infloor PAP Press Tool 24535 and 24538 User Manual

Page 9

background image

9

D, Mount back the pin and the butterfly-shape screw onto the pressing tool. Put the pressing tool on

right position and close the handles to finish the pressing procedure.

E, Release and remove the butterfly-shape screw and the pin from the pressing tool, if necessary take

off the lengthened handles,then open the jaws and move the pressing jaws away from the pressed

fitting without opening the handles or lengthened handles.

G, Mount back the pin and the butterfly-shape screw onto the pressing tool. The pressing at corner or

narrow space is then completed.

6, Pressing F5 (U-profile) fittings with the pressing tool

A, When pressing F5 series fittings, place the jaw's end align with the press sleeve’s end which is by

the plastic ring, close the pressing tool completely.