Infloor PAP Press Tool 24535 and 24538 User Manual
Page 6
6
Pressing-Force to fully close the pressing tool jaws should be about 33 LBS. If not, then the pressing
tool need adjustment before use, please refer to next step for adjustment.
Step3, Adjustment for pressing tool
A, Open the pressing tool and release the "locking screw" (Part No. 13) counter-clockwise for about 3
rounds.
B, If the Trial-Pressing-Force is too small, you should turn the "adjusting screw”
(Part No. 14) clockwise for about 1/4 round. If the Trial-Pressing-Force is too big, then you should
should turn the "adjusting screw" counter-clockwise . You should repeat this process until the Trial
-Pressing -Force is about 33 LBS.
Note:The adjusting screw (Part No. 14) should not be touched again when the Trial-Pressing-
Force reaches about 33 LBS, the pressing tool adjustment should be immediately
locked by locking screw (Part No. 13) at the next step to finish the adjustment.