beautypg.com

Infloor Thermostat 29001 User Manual

Instruction manual

background image

Description

29001 digital non-programmable thermostat is designed to control either

ambient(air) temperature (A Mode) or floor temperature (F Mode) or a

combination of ambient temperature with floor temperature limits(AF Mode). An

auxiliary remote sensor is provided to measure slab temperature in order to

control the floor temperature(within maximum and minimum limits in AF Mode). It

can also be used for sensing the outdoor temperature.

LCD Description

INSTRUCTION MANUAL

Digital Non-Programmable Universal

Thermostat 29001

Radiant Floor Heating

Installation

1. Look for a location which has a constant

temperature in the house and it is not near the

door entry of heater or air conditioning outlet.

The mounting height should be about five feet

above the floor.

2. Insert a screw driver into the slot located on the

right side of the thermostat to open the front

cover.

3. Set the slide switches on the back of the control

module if necessary. Default: AF mode,

°

F

display.

4. Place base over hole in wall and mark

mounting hole locations on wall using base as

a template.

5. Move base out of the way. Drill mounting holes and use the screws

provided to secure the base. Use plastic anchors if necessary.

6. Through the base opening, connect wires to the terminal blocks on the

base according to Figure 2 below.

7. Carefully line the thermostat up with the base and snap into place.

Wiring Diagram

R: 24VAC Hot

C: 24 VAC Common

S, S: auxiliary remote sensor(P-01)

1, 2: relay switch output

Note:

The sensor wires can be

extended by conventional wires.

R C S S 1 2

Figure 2

R C S S 1 2

Heating

Control

24 Vac

Input

Sensor

Slide Switch

The Slide Switches are located at the back of the control module(see Figure 1).

Temperature Display Switch(S1)

: to switch between

°

°

.

Mode of Operation Switch(S2):

A: controls and displays the ambient temperature. Optional: connect external

sensor for the display of outdoor temperature in the upper LCD - also

set Outdoor Sensor to ON in the setting mode.

F: controls and displays the floor temperature. Connect external slab

sensor. Also displays current ambient temperature in the upper LCD.

AF: controls and displays the ambient temperature. Maintains the floor

temperature within desired maximum and minimum limits. Connect external

slab sensor. Also displays current floor temperature in the upper LCD.

I

C and F

C

F

AF F A

Figure 1

Setting Temperature(Setpoint)

Room

885

° °

F C

SYSTEM

Heat

Off

Heat On

AF

Sensor Err

SET MODE
VIEW MODE

Backlit: On Off Auto

885

Room

Floor

OutDoor

888.

8

888

Floor Max Min

Set

SYSTEM

Heat

Off

Heat On

AF

Sensor Err

SET MODE
VIEW MODE

Backlit: On Off Auto

888

Room

Floor

OutDoor

Current Temperature

Backlit mode
Unit of measure

Keypad lock

Operation Mode(A, F or AF)

Heat contact is ON

Operation Mode

(eg. F Mode)

Current Temperature of

indicated area (eg. Room)

Current Temperature of

indicated area(eg. Floor)

related to

operation mode

System Mode

Down Key

Up Key

Set Key

Power Key

Home Screen Display During Operation

Power-up

As soon as the thermostat is powered, all the LCD segments are displayed.

Then it undergoes a series of tests before displaying the actual

temperature.

SETTING THE THERMOSTAT

QuickSet Feature:

Quickset allows the user to change the setpoint temperature instantly without

entering the setting mode. Simply press UP (increase) or Down (decrease)

key during the normal operating mode. When the Up/Down key is pressed, the

setpoint is flashing on the upper right hand corner of the LCD display to indicate

that the setpoint value can be changed. Press the UP/Down k ey again to

adjust the setpoint (press and hold for auto repeat function). Just walk away

when finish and it will return to normal operating mode after 30 seconds.

Setting Mode:

General Note:

Press and hold the Up Key or Down Key to change the value continuously

(auto repeat function).

To return to normal operating mode from the setting mode, press and hold

the SET key for 3 seconds. However, the system also returns to normal

operating mode if no key is pressed for 30 seconds.

During the setting mode, symbol “SET MODE” is displayed on the upper

left corner of the LCD. Each time SET key is pressed, the data will be saved

into the EEPROM and advance to the next setting(parameter). If no

change of value is required, just press

SET key once to go to the next step

(parameter).

Floor Minimum and Maximum limits(AF Mode only)

The thermostat generally turns On or Off to control the ambient temperature.

However, if the floor temperature drops below the set minimum floor

temperature limit, the thermostat will turn heating On regardless of the ambient

temperature. If the floor temperature rises above the maximum limit, the

thermostat will turn heating Off regardless of the ambient temperature to

maintain the floor within the desire limit.

This setting ensures a minimum floor temperature at all times. The maximum

limit is to avoid damage to your floor and for added safety.

Note: The floor minimum limit cannot be set to a higher value than the

maximum limit.

Do Not

Use

Room

885

SYSTEM

Heat

Off

Heat On

AF

Sensor Err

SET MODE
VIEW MODE

Backlit: On Off Auto

885

Room

Floor

OutDoor

888.

8

888

Floor Max Min

Set

SYSTEM

Heat

Off

Heat On

AF

Sensor Err

SET MODE
VIEW MODE

Backlit: On Off Auto

888

Room

Floor

OutDoor

Indicates if current

temperature is Floor

or Room(Ambient)

Shows during

SET MODE

Shows during

VIEW MODE

Default: F

Default: AF

24Vac

Circuit

Isolated

End

Switch (2A)

(S1)

(S2)