beautypg.com

Infloor Electric Cable Series 386 User Manual

Page 6

background image

IOM-INF-Cable 1434

6 of 36

240 VAC

Model

Number

Total Sq. ft.

2.5" Spacing

15 watts/ft

2

Total Sq. ft.

3" Spacing

12 watts/ft

2

Total Sq. ft.

3.5" Spacing

10 watts/ft

2

Wire

Length

(ft.)

Amp

Draw

Resistance

(ohms)

38730

17

20

24

78

1.0

217 - 267

38731

25 30 36

117

1.5

143

-

176

38732

34 40 48

157

2.0

107

-

132

38733

42

50

60

196

2.5

84 - 104

38734

51

60

72

235

3.0

67 - 83

38735

59

70

84

274

3.5

59 - 73

38736

67

80

96

313

4.0

50 - 63

38737

76

90

108

352

4.5

45 - 56

38738

84

100

120

391

5.0

40 - 50

38739

101

120

144

470

6.0

33 - 42

38740

118

140

168

548

7.0

29 - 37

38741

135

160

192

626

8.0

24 - 31

38742

151

180

216

704

9.0

22 - 28

38743

168

200

240

783

10.0

20 - 26

Table 2 - Cable sizes

Please check the product label for exact ratings. This table is for reference only.

120 VAC

Model

Number

Total Sq. ft.

2.5" Spacing

14.4 watts/ft

2

Total Sq. ft.

3" Spacing

12 watts/ft

2

Total Sq. ft.

3.5" Spacing

10.3 watts/ft

2

Wire

Length

(ft.)

Amp

Draw

Resistance

(ohms)

38630

8

10

12

39

1.0

108 - 134

38631

13

15

18

59

1.5

72 - 89

38632

17

20

24

78

2.0

53 - 66

38633

21

25

30

98

2.5

42 - 52

38634

25

30

36

117

3.0

33 - 42

38635

29

35

42

137

3.5

29 - 37

38636

34

40

48

157

4.0

25 - 32

38637

38

45

54

176

4.5

22 - 28

38638

42

50

60

196

5.0

20 - 26

38639

51

60

72

235

6.0

16 - 21

38640

59

70

84

274

7.0

14 - 19

38641

67

80

96

313

8.0

12 - 16

38642

76

90

108

352

9.0

11 - 14

38643

84

100

120

391

10.0

10 - 13

It is important to select the proper size cable for the given area. Infloor Electric Cable
cannot be cut shorter in order to fit a given area. Doing so will damage the heating wire
and prevent the system from working.

This manual is related to the following products: