Items needed, Materials, Tools – Infloor Electric Cable Series 386 User Manual
Page 5
5 of 36
Copyright ©2014
Installation must be performed by qualified personnel, in accordance with local codes
and standards. A licensed electrician is recommended.
ALWAYS make sure all electrical work is done by qualified persons in accordance with local
building and electrical codes, Section 62 of the Canadian Electrical Code (CEC) Part I, and
the National Electrical Code (NEC), especially Article 424.
ALWAYS use copper only as supply conductors to the thermostat. Do not use aluminum.
ALWAYS seek help if a problem arises. If ever in doubt about the correct installation proce-
dure to follow, or if the product appears to be damaged, the factory must be called before
proceeding with the installation.
Before installing Infloor Electric Cable, make sure to fully inspect the products and carefully
plan the site.
Items Needed
Materials:
• Infloor Electric Cable
system
• Wire Strap (provided with the cable)
• Infloor
thermostat with floor sensor
• Infloor Relay control (if required)
• Control electrical box (UL Listed, extra deep, see control instructions for size and type required)
• Infloor Sensor Tube p/n 29011
• Junction electrical box (if required, see Step 2.2)
• Wire nuts (if a junction electric box is required, see Step 2.2, must be UL Listed and
proper size)
• Flexible or rigid conduit (if required, see Step 2.4, must be UL Listed and proper size)
• 12-guage or 14-guage electrical wiring cable (UL Listed, see Step 2.1)
• Nail plate
Tools:
• Digital multi-meter (for ohms testing; must read up to 20,000 ohms (Ω) to measure sensor)
• Drill with 1/2" and 3/4" bits
• Hammer and chisel
• Got glue gun and hot glue (craft grade)
• Wire strippers
• Phillips screwdriver
• Fish tape
• Hole saw
• Floor covering installation tools
Phase 1 - Preparations
Floor sensor
is included in
the thermostat
packaging. This must
be installed in the
floor with the cable.