Test 1 – voltage input – Hypertherm Powermax30 XP Service Manual User Manual
Page 74

74
Powermax30 XP Service Manual 808150 Revision 1
5 – Troubleshooting and System Tests
Test 1 – voltage input
Check the incoming voltage and the line voltage to the top of the power switch (S1).
1. Set power switch to OFF (O), disconnect the power cord from the power source, and disconnect the gas supply.
2. Remove the power supply handle and cover. (See Remove the power supply cover on page 88.)
3. Remove the component barrier. (See Remove the component barrier on page 90.)
4. Partially pull the power switch’s top two wires out from the tabs and attach the multimeter test leads to the tabs to
check the AC voltage.
5. Once you have the test leads in place, leave the power switch set to OFF (O), and reconnect the electrical power.
The voltage should equal the line voltage of the incoming circuit, for example 120 V or 240 V.
All values can be ±15%.
WARNING!
ELECTRIC SHOCK CAN KILL
Use extreme caution when working near live electrical circuits. Dangerous
voltages exist inside the power supply that can cause serious injury or death.
See the WARNING! on page 58 before proceeding.