4 – Operation
Operating the system on a 120 V, 15 A circuit
Set the amperage below 20 A, as indicated by the
gray shading around the knob (the inner ring).
Use only the FineCut nozzle (420117) and deflector
(420115); do not use the general-purpose (standard)
nozzle (420118) or shield (420116).
Verify that nothing else is drawing power from the
circuit.
Operating the system on a 120 V, 20 A circuit
Set the amperage below 25 A, as indicated by the
blue shading around the knob (the middle ring).
Use only the FineCut nozzle (420117) and deflector
(420115); do not use the general-purpose (standard)
nozzle (420118) or shield (420116).
Verify that nothing else is drawing power from the
circuit.
Operating the system on a 240 V, 20 A circuit
Set the amperage between 15 – 30 A.
Use either the general-purpose (standard) or the
FineCut consumables.
Do not mix the general-purpose and FineCut
consumables. Use one set or the other.
See
Voltage configurations on page 25 for more
information.
Use only the FineCut consumables
when operating the system on a
120 V input circuit.
120 V
420116
420118
FineCut
420115
420117
20
25
AMPS
240 V
20 A
120 V
20 A
120 V
15 A
15
30
Gray shading
20
25
AMPS
240 V
20 A
120 V
20 A
120 V
15 A
15
30
Blue shading
20
25
AMPS
240 V
20 A
120 V
20 A
120 V
15 A
15
30