6 – Power Supply Component Replacement
3. Push-to-disconnect the gas supply hose from the fitting on the rear-panel side of the solenoid valve. (See Figure 56
4. Push-to-disconnect the gas supply hose from the fitting on the front-panel side of the solenoid valve.
Figure 64
5. Remove the 2 screws that attach the solenoid valve’s bracket to the center panel.
6. Orient the new solenoid valve so that the pink-and-gray J6 wire pair is on the rear-panel side of the valve.
Figure 65
2
1
4
3
1
Gas supply hose (rear-panel side)
2
Solenoid valve
3
Gas supply hose (front-panel side)
4
J6 wire pair
1
3
2
1
(Rear panel)
(Front panel)
1
Push-to-connect fitting
2
Pink-and-gray J6 wire pair
3
Solenoid valve bracket
This manual is related to the following products: