beautypg.com

Powermax30, Controls and indicators, Operation – Hypertherm Powermax30 Operator Manual User Manual

Page 64: Rear controls, Front controls and leds

background image

OPERATION

4-2

powermax30

Operator Manual

Controls and indicators

The Powermax30 has an ON/OFF rocker switch, an amperage adjustment knob and 4 indicator
lights, which are described below.

I

O

120V 15A

120V 20A
240V 20A

I

O

Rear controls

ON (I)/OFF (O) power switch

Activates the power supply and its control circuits.

Gas pressure LED (yellow)

When illuminated, this LED indicates
that the gas pressure is below 40 psi
(2.8 bar). Correct this condition before
you continue.

Torch cap LED (yellow)
When illuminated, this LED indicates
that the consumables are loose,
improperly installed, or missing.

Power ON LED (green)
When illuminated, this LED indicates
that the power switch has been set at I
(ON) and that the safety interlocks are
satisfied.

AC

AC

Front controls and LEDs

Temperature LED (yellow)

When illuminated, this LED indicates
that the power supply temperature is
outside the acceptable operating
range.

Amps adjustment knob

Use this knob to set the output
current between 15 and 30 amps.

Front

Rear

Some fault conditions will cause one or more of the LEDs to blink. For information on what these
fault conditions are and how to correct them, see Basic troubleshooting in Section 5.

PMX30_OM_04.qxp:PMX30_OM_04 10/7/09 12:45 PM Page 4-2