1-6

Hypertherm

SAFETY

11/08

• Never lubricate cylinder valves or regulators with

oil or grease.

• Use only correct gas cylinders, regulators, hoses

and fittings designed for the specific application.

• Maintain all compressed gas equipment and

associated parts in good condition.

• Label and color-code all gas hoses to identify

the type of gas in each hose. Consult applicable
national or local codes.

GAS CYLINDERS CAN
EXPLODE IF DAMAGED

COMPRESSED GAS EQUIPMENT
SAFETY

Gas cylinders contain gas under high pressure.
If damaged, a cylinder can explode.

• Handle and use compressed gas cylinders in

accordance with applicable national or local
codes.

• Never use a cylinder that is not upright and

secured in place.

• Keep the protective cap in place over valve

except when the cylinder is in use or connected
for use.

• Never allow electrical contact between the

plasma arc and a cylinder.

• Never expose cylinders to excessive heat, sparks,

slag or open flame.

• Never use a hammer, wrench or other tool to

open a stuck cylinder valve.

Work Cable

Attach the work cable securely to the

workpiece or the work table with good metal-to-metal
contact. Do not connect it to the piece that will fall
away when the cut is complete.

Work Table

Connect the work table to an earth

ground, in accordance with appropriate national or
local electrical codes.

Input Power

• Be sure to connect the power cord ground wire

to the ground in the disconnect box.

• If installation of the plasma system involves

connecting the power cord to the power supply,
be sure to connect the power cord ground wire
properly.

• Place the power cord's ground wire on the stud

first, then place any other ground wires on top
of the power cord ground. Fasten the retaining
nut tightly.

• Tighten all electrical connections to avoid

excessive heating.