Powermax30, Power cord considerations – Hypertherm Powermax30 Operator Manual User Manual
Page 58

SETUP
1
3-4
powermax30
Operator Manual
Power cord considerations
Powermax30 power supplies are shipped with CSA and CE power cord configurations.
Power cord and plugs for CSA power supplies
The power cords on the CSA power supplies are shipped with a 120V/15A (NEMA 5-15P) plug
adapter and a 240V/20A (NEMA 6-50P) plug adapter in addition to the twist-lock 240V/20A
(NEMA L6-20P) plug wired to the system. A 120V/20A plug adapter is available as an accessory.
See Section 5, Powermax30 accessory parts, for part number information.
• The power cord on the Powermax30 power
supply is equipped with a twist-lock plug
(NEMA L6-20P) appropriate for use on a
240V/20A circuit with a twist-lock outlet.
• To operate the Powermax30 on a lower
amperage circuit, attach the female end of the
120V/15A (NEMA 5-15P) plug adapter to
the power supply's twist-lock plug.
Note: Do not set the amperage adjustment
knob above 20A or your circuit
breaker may trip. See Section 4,
Power on the system, for more
information.
• To operate the Powermax30 on a 240V/20A
circuit, attach the female end of the
240V (NEMA 6-50P) plug to the power
supply's twist-lock plug.
PMX30_OM_03.qxp:PMX30_OM_03 10/7/09 12:44 PM Page 3-4