beautypg.com

Power supply ratings, Specifications powermax30 – Hypertherm Powermax30 Operator Manual User Manual

Page 51

background image

SPECIFICATIONS

powermax30

Operator Manual

2-3

Power supply ratings

Rated open-circuit voltage (U

0

)

240 VDC

Rated output current (I

2

)

15 A to 30 A

Rated output voltage (U

2

)

83 VDC

Duty cycle at 40° C, U

1

=120 VAC

(See data plate on power supply for
more information on duty cycle.)

35 % (I

2

=30 A, U

2

=83 V)

60 % (I

2

=23 A, U

2

=83 V)

100 % (I

2

=18 A, U

2

=83 V)

Duty cycle at 40° C, U

1

=200–240 VAC

50 % (I

2

=30 A, U

2

=83 V)

75 % (I

2

=24 A, U

2

=83 V)

100 % (I

2

=21 A, U

2

=83 V)

Operating temperature

14° to 104° F (-10° to 40° C)

Storage temperature

-13° to 131° F (-25° to 55° C)

Power factor (120 V – 240 V)

0.99 – 0.97

Input voltage (U

1

)/ Input current (I

1

) at

rated output (U

2 MAX

, I

2 MAX

)

120 V / 26 A

200-240 V / 15,5-13 A

Gas type

Air

Nitrogen

Gas quality

Clean, dry, oil-free

99.995 % pure

Minimum required gas inlet pressure
and flow

3.5 scfm @ 65 psi (99.1 l/min @ 4.5 bar

Recommended gas inlet flow
and flow

4.0 scfm @ 80 psi (113.3 l/min @ 5.5 bar)

PMX30_OM_02.qxp:PMX30_OM_02.qxd 10/7/09 12:44 PM Page 2-3