beautypg.com

Safety – Hypertherm PHC Sensor User Manual

Page 7

background image

Safety

1

Safety


Read this Manual

Read and understand this manual, the cutting machine manuals, and your employer’s safety practices.   
Note:  This product is not designed to be field serviceable.  Return this product to an authorized repair center 
for service. 

Sensor PHC Safety Listing


Note: This product has been designed and manufactured in accordance with CE and UL Safety Standards.

UL has successfully tested and listed this product in accordance with the applicable U.S. and Canadian Safety
Standards. File number E307226.
Additional markings:

1) Use minimum 75

0

C copper wire only. 

2) Use copper conductors only. 
3) Suitable for use on a circuit capable of delivering not more than 5000rms symmetrical amperes, 

230 volts maximum. 

4) Integral solid state short circuit protection does not provide branch circuit protection.  Branch 

circuit protection provided by integral LISTED branch circuit protection fuse. 

5) “Solid state motor overload protection is provided at 145% of full load current”, or the equivalent.