System specifications – Hypertherm PHC Sensor User Manual
Page 11

Section 1: Overview
11
System Specifications*
Compatible motors:
DC PM 24Vdc, 2 Amps to 6 Amps
Max power output:
150W
Standard lifter range:
Linear 6” (152mm)
Motor output:
Full “H” bridge PWM with current & voltage sensing
Accuracy:
0.01” (.25mm ) or 0.5 Volt **
Voltage control range:
50 Vdc to 210 Vdc
IHS range:
0.05 inches (1.2 mm) to 0.5 inches (12 mm) **
Operator controls:
Arc voltage, IHS height, & pierce delay control knobs
Operator switches:
IHS test, auto / manual, & manual up / down
Operator display:
3 digit 7 segment display for set volts, actual volts, & error
Calibration adjustments:
Arc voltage, stall force, auto kerf detect level
Setup DIP switches:
Max motor current, arc voltage response, IHS speed, auto delay,
int/ext pierce delay, end of cut retract height, auto kerf detect,
preflow during IHS, limit switches, breakaway switch, arc voltage
calibration
Measuring technology:
Arc voltage feedback & ohmic contact sensing
Interface inputs/ outputs:
8 outputs and 6 inputs optically isolated on “D” connectors
Control dimensions:
6.2”(157mm)W x 4.3”(1.9mm)D x 10.4”(264mm)H
Control weight:
9 lbs
Control power:
115VAC 0r 230VAC +/- 10% 50/60 Hz –selectable
Standard lifter dimensions:
6”(152mm)W x 3.15”(80mm)D x 21.5”(546mm) **
Standard lifter weight:
19 lbs **
Operating environment:
0 to 50C; 95% relative humidity (non-condensing)
*Information subject to change without notice.
** With Standard supplied lifter mechanics