beautypg.com

System specifications – Hypertherm PHC Sensor User Manual

Page 11

background image

Section 1: Overview

11

System Specifications*

Compatible motors:

DC PM 24Vdc, 2 Amps to 6 Amps

Max power output:

150W

Standard lifter range:

Linear 6” (152mm)

Motor output:

Full “H” bridge PWM with current & voltage sensing

Accuracy:

0.01” (.25mm ) or 0.5 Volt **

Voltage control range:

50 Vdc to 210 Vdc

IHS range:

0.05 inches (1.2 mm) to 0.5 inches (12 mm) **

Operator controls:

Arc voltage, IHS height, & pierce delay control knobs

Operator switches:

IHS test, auto / manual, & manual up / down

Operator display:

3 digit 7 segment display for set volts, actual volts, & error

Calibration adjustments:

Arc voltage, stall force, auto kerf detect level

Setup DIP switches:

Max motor current, arc voltage response, IHS speed, auto delay,
int/ext pierce delay, end of cut retract height, auto kerf detect,
preflow during IHS, limit switches, breakaway switch, arc voltage
calibration

Measuring technology:

Arc voltage feedback & ohmic contact sensing

Interface inputs/ outputs:

8 outputs and 6 inputs optically isolated on “D” connectors

Control dimensions:

6.2”(157mm)W x 4.3”(1.9mm)D x 10.4”(264mm)H

Control weight:

9 lbs

Control power:

115VAC 0r 230VAC +/- 10% 50/60 Hz –selectable

Standard lifter dimensions:

6”(152mm)W x 3.15”(80mm)D x 21.5”(546mm) **

Standard lifter weight:

19 lbs **

Operating environment:

0 to 50C; 95% relative humidity (non-condensing)

*Information subject to change without notice.
** With Standard supplied lifter mechanics