Fireplace Installation

Option #3 - Hardwire

Wire a dedicated, properly

fused circuit with 120 volt,

15 Amp rating. Allow up to eight

(8) feet (2.4 m) of service cable

for connecting power supply to

junction box on fireplace when

installing after finishing wall.

CAUTION: Use two

conductor, non-metallic sheath

cable with ground wire (three

(3) wires total) for the incoming

power supply on fireplace

inserts. Use appropriate wire

to meet local and national

electrical codes for rated

power consumption.

Remove the outer jacket and

strip the individual conductor from

the end.

Loosen the screw securing

the junction box cover and

remove the cover.

Take the cables out from the

junction box, loosen the two wire

twist nuts and remove the cord

set (Figure 2).

Route the power supply wire

through the knockout on supplied

alternative junction box cover

and secure with a wire clamp (not

supplied) (Figure 3).

Connect the black wire (live)

from the unit to the black wire

from power supply (Figure 3).