www.dimplex.com

Fireplace Installation

Connect the white wire

(neutral) from the unit to the white

wire from power supply

(Figure 3).

Connect the green wire

(ground) from the unit to the

green wire from power supply

(Figure 3).

Place all connectors inside

the unit and secure the junction

box cover to unit. Ensure that the

cable clamp grips only the jacket

of service cable.

CAUTION:

Clearance for

air circulation beneath the

fireplace insert is provided by

two (2) rubber feet.

Do not install the fireplace

insert directly on carpet or

similar surfaces which may

restrict air circulation.

if installing the fireplace in a

carpeted area, place a one-

piece, solid, flat surface under

the fireplace insert. ensure

that both of the insert’s feet

rest securely on this surface.

Final Steps
Carefully pour and evenly

distribute the supplied glass rock

media on the front tray of the

firebox (Figure 4). once complete,

hang the front glass assembly on

the mounts of the firebox.

Fireplace

Junction

box

White wire (N)

black wire (l)

Green wire (G)

Green wire (G)

black wire (l)

White wire (N)

120 v power

Supply

(breaker panel)

Figure 4

Front glass

Mounts

hooks