Gullco GK-200-RLx-A User Manual
Page 11

9
the Weld Direction is detected and not activated, then the Post Weld Delay timing
cycle is initiated and the cycle proceeds as per section 19.
19. Upon completion of the Post Weld Delay (keeping the carriage stationary to allow time for
any burn-back or post flow welding functions), the cycle will continue as per section 20.
20. The carriage will travel in the opposite direction to that of the Weld Direction parameter, at
full speed, until the activation of the home limit switch (limit switch in opposite direction to
that of the Weld Direction parameter). The cycle then proceeds to section 21.
21. Upon the activation of the home limit switch the carriage return travel will immediately stop
and the cycle is then completed and “End” is displayed.
Programming The Automatic Cycle Parameters/Variables
The Cycle Push Button is used to enter the programmable parameters menu that allows the
operator to change their values and settings and so define how the automatic cycle will function.
The Cycle Push Button is located between and above the Run/Stop switch and the
Forward/Neutral/Reverse switch of the GSP control.
To make changes to the program variables, turn the power turned on and place the Run/Stop
switch in the Stop position and the Fwd/Neut/Rev switch in the Neutral position, then press and hold
the cycle push button (approximately 5 seconds) until the control acknowledges programming mode
has been entered by displaying the first parameter screen “P1”. By rotating the speed adjustment
knob clockwise the operator can navigate to the next parameter “P2”. Clockwise rotation will
increment the program variable number while counterclockwise rotation will decrement the program
variable.
Once the desired parameter has been selected the display screen will automatically alternate
between the parameter number (P#) and the programmable parameter/variable that is assigned to
it. Changes made by placing the Fwd/Neut/Rev toggle switch in either Fwd or Rev and then rotating
the speed adjustment knob to change the value of the parameter. For numeric values, clockwise
rotation will increase while counter clockwise rotation will decrease the value.
To exit programming mode, push and hold the Cycle Push Button until the control acknowledges it
has exited programming mode by returning the main screen.
Cycle Push Button