Gullco GK-200-RLx-L User Manual
Page 18

16
ERROR CODES
Error codes are displayed on the LCD screen as shown adjacent.
ER.1
If the Oscillator Controls’ Manual/Hold/Auto switch is in the
Auto position on power-up, the control will display ER.1 and
not permit an automatic cycle to start. This prevents the
undesirable start of an automatic cycle on power-up. To
reset the error, place the switch in the Hold position.
ER.2
When the Oscillator Control is programmed to operate a Linear Oscillator Head (preferred units
of measurement are either Inches or CM), the control monitors limit switches located within the
Oscillator Head to prevent over-travel. If either, or both, of these limit switches are open circuit,
the control will display ER.2 and not permit normal operation. This situation could include the
following possibilities:
Manually jogging the slide too far. To reset, manually jog the slide in the opposite
direction.
The over-travel occurred during Oscillation. This could be due; to the oscillation
width being set too large for the stroke of the slide; the starting location of the
oscillator slide relative to the oscillation width and direction; or through making center
position adjustments (steering), resulting in slide over-travel. To reset, make the
necessary manual and/or programming adjustments and restart the automatic cycle.
It is recommended that the oscillator be set so that the oscillation occurs in the
centre of the slides stroke to permit center position adjustments (steering) without
activating the over-travel limit switches.
Powering up the “KAT”
®
Carriage/Compact Oscillator without having a Linear Head
connected. To reset, either power down and attach a Linear Oscillator Head or
connect a Radial Oscillator Head and reprogram the Oscillator Control accordingly.
o
WARNING!
Always turn the main power off before
connecting/disconnecting the oscillator head cable to/from the “KAT”
®
carriage.
Failure to comply may result in control damage.
OPTIONAL ACCESSORIES
GK- 201-121 Optional Audible Buzzer Kit – Includes audible buzzer and wiring harness to
interface with the Oscillator Control, providing a programmable duration for the
audible warning buzzer to activate before starting an automatic cycle.