Gullco GK-200-RLx-L User Manual
Page 16

14
3
rd
Field = Travel Motion Delay. This sets a timing delay at the start of an automatic cycle, from
the time that the arc activation signal is energized until the time that the travel carriage
Hold (stop) signal is de-energized. I.e. a timing cycle to allow the arc to strike and
establish, before carriage motion. The choices available are from 0.0 to 9.9 seconds
in 0.1 second increments. The factory default setting is 0.3 seconds.
4
th
Field = Crater Fill Delay. This sets a timing delay at the end of an automatic cycle, from the
time that the travel carriage Hold (stop) signal is re-energized and the oscillation
motion stops until the arc activation signal is de-energized. I.e. a timing cycle to allow
the welding to continue after the welding motion ceases. The choices available are
from 0.0 to 9.9 seconds in 0.1 second increments. The factory default setting is 0.5
seconds.
5
th
Field = Oscillation Rest Location. This setting dictates where the oscillator stops at the end of
an oscillation cycle (and therefore assumed location at the start of an oscillation cycle).
The choices are A, B or C. The factory default setting is B.
6
th
Field = Audible Warning Buzzer Duration. This sets the timing cycle for the optional audible
warning prior to the start of each Auto cycle. The choices are from 0 to 9 seconds in 1
second increments.
When the value is greater than 0, the following icon is displayed:
When the value is 0, the following icon is displayed:
Notes: All fields except the 1
st
Field retain the last value entered.