beautypg.com

Operation – Gullco GM-03-300 User Manual

Page 9

background image

7

OPERATION

The GM-03 series of “MOGGY” carriages use Gullco’s sophisticated “GSP” microprocessor motor
controls.

 GM-03-350 model uses GSP-2000-9 motor controls

 GM-03-300 model uses GSP-2010-10 motor controls.

GSP Control Overview

The following provides a brief description of the GSP controls (refer to the above sketch):

The Cycle Push Button – is a momentary device, which when pressed for one second while the
Run/Stop switch is in the Stop position, will toggle between Manual Mode (Hnd) and Automatic
Mode (Aut). When in Automatic Mode the Auto Cycle Mode LED will be illuminated.

The Cycle Push

Button is also used to increment/decrement the values/settings of the program variables (refer to the section
“Programming The Automatic Cycle Parameters/Variables” later in this manual for further details of this
function).

The Run/Stop Switch – is used to start and stop the “MAGNETIC MOGGY” carriage in either
Manual Mode or Automatic Mode. The Hold (Stop) position is also used to reset most error codes
once they have been rectified.

Command Forward Motion

Speed & Parameter Value
Display

Speed Display Calibrated in
Inches per Minute

Speed Display Calibrated in
Centimeters per Minute

Auto Cycle Mode (Constant)
Programming mode (Flashing)
Manual Mode (Absent)

Speed Adjustment
Counter-Clockwise = Slower
Clockwise = Faster

Neutral

Command Reverse Motion

Program Variable Selector Switch

(Extended or Recessed)

Control in Run Mode

Cycle Push Button

(Extended or Recessed)

Arc Signal Active

Hold (Stop) Mode Active

Reverse Motion Commanded

Forward Motion Commanded

Control in Hold (Stop) Mode

This manual is related to the following products: