Table 6.
DIP Switch S4 Default Settings
DIP Switch S4
Function
Settings
S4-1 Open
S4-2
Baud rate = 19.2 k
Open
S4-3 N/A
Open
S4-4 N/A
Open
S4-5 N/A
Open
S4-6
Wait for poll request
from master
Open
S4-7
Return address to
master controller
Open
S4-8
Do not signal data
fault with master
Closed
Reset Switch
A small push-button switch is provided to restart the I/O controller’s microprocessor. Momentarily press
the button to initiate the reset sequence.
Specifications
Power Supply Requirements
Connection to a 12 to24 V dc (UL listed) Class 2 power source ..................................... 600 mA minimum
Power consumed ............................................................................................................7 watts maximum
Auxiliary outputs.................................................... Sink 150 mA maximum, per output to circuit common
and pulled up to the power input voltage
Mechanical
Enclosure .................................................................Steel body and cover; black fine-textured paint finish
Mounting .............................................................................................................................. Wall or shelf
Dimensions ..........................................................7.50 W
× 5.625 D × 1.02 H inches (191 × 143 × 26 mm)
Weight ............................................................................................................................. 2 lbs. (0.902 kg)
Environmental
Temperature range................................................................................ +32º F to +122º F (0º C to +50º C)