Control tones, Tone levels, Accessories – GAI-Tronics ITR2000A Tone Remote Deskset User and Installation Manual User Manual
Page 11

ITR1000A Tone Remote Desk Set
Description
7
02/12
Control Tones
Standard EIA tone keying tones are used for controlling the radio system. The sequence is:
A 2175 Hz High Level Guard Tone (HLGT) for 120 ms.
One of 16 function tones (FT) is sent for 40 ms.
FTs range from 2050 Hz to 550 Hz in 100 Hz steps. The FT level is 10 dB lower than the HLGT.
Monitor
2050
FT4
1650
FT8
1250
FT12
850
FT1
1950
FT5
1550
FT9
1150
FT13
750
FT2
1850
FT6
1450
FT10
1050
FT14
650
FT3
1750
FT7
1350
FT11
950
FT15
550
A 2175 Hz Low Level Guard Tone (LLGT) is generated for the duration of the transmission. The
LLGT is not generated during monitor. Because voice is present with this LLGT, a 2175 Hz filtering
is required in the tone panel.
When the monitor (CTCSS disable) is activated, the HLGT is generated for 120 ms, then a function tone
of 2050 Hz is generated for 40 ms.
Tone Levels
Assuming that the ITR2000A has the HLGT output level set to 0 dBm:
The FT level and audio voice level are –10 dBm (10 dB below HLGT)
The LLGT level is –30 dBm.
The HLGT and FT durations are programmable.
Some tone panels use the value of the FT frequency to provide certain radio control functions. If the
radio supports channel changes from an external logic source, the FT1 frequency of 1950 Hz could be
used to change the radio to channel 1. An FT6 frequency of 1450 Hz could change the radio to
channel 6.
Accessories
Description Part
No.
GAI-Tronics Programming Bundle CD
XAC4000A
Desk Microphone
XDM004A
Footswitch (requires XAAB002A) XFS002A
Gooseneck Microphone
XGM002A
Amplified Headset, Single Earpiece (requires coiled cord)
XHS003C
Coiled Cord for XHS003C (requires XAAB002A)
XCC004B
Coiled Cord with PTT for XHS003C (requires XAAB002A)
XCC003C
Programming Cable
XAC0004A
Audio Accessory Box
XAAB002A