Fault Message
Cause and Effect
Possible Solution
Polled End-of-line
device
Cause—This message is the same as the
“Polled device” fault, except that the affected
station has been defined as an end-of-line
station in the MCU configuration.
Effect—When this fault occurs, the red EOL
FLT LED on the PPI bezel lights. When
communication is resumed, the LED
extinguishes and a restore message is sent to the
MCU.
Verify that the page line
is connected and intact.
Verify that the station is
installed correctly.
Replace the station
assembly.
Specifications
Electrical
Supply voltage .......................................................................... 90–140 V ac (120 V ac nominal), 50/60 Hz
Power consumed @ nominal ac ........... Zero/maximum signal (12 watts): 15 VA, 9 watts/59 VA, 32 watts
Speaker Amplifier
Output ............................................................................... 12 watts minimum, with nominal supply voltage
Frequency response .......................................................................... 350–6,500 Hz, +0/−3 dB, ref. to 1 kHz
Distortion ......................................................................................... 1% maximum THD @ 1 kHz, 12 watts
SmartVolume™
Monitor range (low gain) ...................................................................................................... 62–100 dB SPL
Offset (above ambient) user level adjustment ................................................................................... 0–48 dB
Minimum user level adjustment .................................................................................... Off; 85–125 dB SPL
Mechanical
Dimensions ....................................... 8.12 H
8.12 W 3.12 D inches (206.0 206.0 78.7 mm) overall
Package weight ..................................................................................................................... 6.1 lbs. (2.8 kg)
Net weight ............................................................................................................................. 5.1 lbs. (2.3 kg)
Environmental
Temperature range ......................................... −22° F to +158° F (−30° C to +70° C) operating and storage
Humidity ..................................................................................................................... 95%, non-condensing
Approvals
NRTL Listed USA and Canada .............................................................. Class I, Div. 2, Groups A, B, C, D
when used with a listed GAI-Tronics 702 or 703 Series enclosure
Class I, Div. 2, Groups A, B, C, D;
Class II, Div. 2, Groups F, G; Class III, Div. 2
when used with a listed GAI-Tronics 732, 733, 7325, 7335, or 758 Series enclosure
Temperature code ....................................................................................................................................... T4