Operation – GAI-Tronics 013-020095-002 Elemec3 System Controller User Manual
Page 7

Pub. 42004-480B
Model 013-02-0095-002 Elemec3 System Controller
Page 7 of 11
e:\standard ioms - current release\42004 instr. manuals\42004-480b.doc
05/14
Operation
N
OTE
: Each Elemec3 System Controller is custom-configured for a specific application via the Elemec3
software application. Please refer to your system manual for more information.
The Elemec3 System Controller front panel contains a rotary key switch, three LEDs and a USB port
(reserved for future use).
The key switch provides the capability to turn on or off previously configured inputs.
The LEDs operate in accordance with the following table:
Table 2. Front Panel LED Indications
LED Indication
PA
IN
USE
Green – Indicates the PA system is in use.
Off – Not in use
SYSTEM
STATUS
Green – Normal operation
Red – Fault condition – Refer to the display for additional information.
Blinking Red – Fault acknowledged
Amber – Non-critical fault
PWR
Blue – Power is on.
Off – No power
The E3 Controller has been designed so that it can be monitored over an IP based data network either
locally or remotely. The loss of connection to the data network therefore constitutes a fault condition
which will be duly indicated by the SYSTEM
STATUS
LED on the front of the Controller. For the
correct operation of the E3 Controller it should be connected at all times to a network.