Installation
Mount the Elemec3 System Controller in the 19-inch rack using the supplied hardware.
The following is a discussion of the types of Elemec3 systems that can be configured. Refer to your 
system manual for complete information. 
Single System
In a single type system, the Elemec3 System Controller is typically installed in the top position of a 
standard EIA 19-inch Elemec3 system equipment rack. It requires 1U (1.75 inches) of height. 
Duplicate System
In a “duplicated” or redundant system, two Elemec3 System Controllers, designated as A and B, are 
located in system racks at different location. In this type of system there are two sets of amplifiers (also 
designated as A and B) with the two speaker loops run in different routes. If one Elemec3 System 
Controller should fail, there would be a 50% loss of audible coverage. 
Hot Standby (N+1) System
In a different type of redundant system, referred to as a Hot Standby (N+1), two Controllers, designated 
as A and B, are located in the same cabinet and control a single set of amplifiers. The advantage to this 
type of system is that there is no loss of coverage if one Elemec3 System Controller should fail. 