Table 6. 33-Ohm Connections Channel 2, P12
Pin
Number
Pin Name
Function
1
NC 33-ohm active
Normally closed connection of 33-ohm output VOX detection.
2
COM 33-ohm active
Common connection of 33-ohm output VOX detection.
3
NO 33-ohm active
Normally open connection of 33-ohm output VOX detection.
4
GND
Ground reference for field wiring.
5
L1 33-ohm audio
Bi-directional audio for 33-ohm interface
6
L2 33-ohm audio
Bi-directional audio for 33-ohm interface
Settings and Adjustments
Opening the Station
Remove the four screws from the front panel and place the front panel to the side.
Jumper Settings
Channel 1: 33-Ohm Activation P3 - Install the jumper in the ACT (default) position to enable the 33-
ohm audio output. Install the jumper in the NON position to disable the 33-ohm audio output.
Channel 1: 33-Ohm Termination P8 - The Page/Party
®
line can be terminated to 33 ohms as required
by the Page/Party
®
system. Install the jumper in the TERM position to terminate the line. Install the
jumper in the NON (default) position to leave the line unterminated. For the unterminated position, a
line balance assembly is needed in the system.
Channel 1: 600-Ohm Activation P7 - Install the jumper in the ACT (default) position to enable the
600-ohm audio output. Install the jumper in the NON position to disable the 600-ohm audio output.
Channel 2: 33-Ohm Activation P9 - Install the jumper in the ACT (default) position to enable the
33-ohm audio output. Install the jumper in the NON position to disable the 33-ohm audio output.
Channel 2: 33-Ohm Termination P14 - The Page/Party
®
line can be terminated to 33 ohms as required
by the Page/Party
®
system. Install the jumper in the TERM position to terminate the line. Install the
jumper in the NON (default) position to leave the line unterminated. For the unterminated position, a
line balance assembly is needed in the system.
Channel 2: 600-Ohm Activation P13 - Install the jumper in the ACT (default) position to enable the
600-ohm audio output. Install the jumper in the NON position to disable the 600-ohm audio output.