Audio and Control Signals
The 370-301 allows access to the audio line inputs and output along with relay contacts for the VOX
detection.
Table 3. 600-Ohm Connections Channel 1, P4
Pin
Number
Pin Name
Function
1
NC 600-ohm active
Normally closed connection of 600-ohm output VOX detection.
2
COM 600-ohm active
Common connection of 600-ohm output VOX detection.
3
NO 600-ohm active
Normally open connection of 600-ohm output VOX detection.
4
GND
Ground reference for field wiring.
5
L1 600-ohm audio
Bi-directional audio for 600-ohm interface
6
L2 600-ohm audio
Bi-directional audio for 600-ohm interface
Table 4. 33-Ohm Connections Channel 1, P6
Pin
Number
Pin Name
Function
1
NC 33-ohm active
Normally closed connection of 33-ohm output VOX detection.
2
COM 33-ohm active
Common connection of 33-ohm output VOX detection.
3
NO 33-ohm active
Normally open connection of 33-ohm output VOX detection.
4
GND
Ground reference for field wiring.
5
L1 33-ohm audio
Bi-directional audio for 33-ohm interface
6
L2 33-ohm audio
Bi-directional audio for 33-ohm interface
INTELLECTU
Table 5. 600-Ohm Connections Channel 2, P10
Pin
Number
Pin Name
Function
1
NC 600-ohm active
Normally closed connection of 600-ohm output VOX detection.
2
COM 600-ohm active
Common connection of 600-ohm output VOX detection.
3
NO 600-ohm active
Normally open connection of 600-ohm output VOX detection.
4
GND
Ground reference for field wiring.
5
L1 600-ohm audio
Bi-directional audio for 600-ohm interface
6
L2 600-ohm audio
Bi-directional audio for 600-ohm interface