Troubleshooting, Specifications – GAI-Tronics ICS Page/Party Desktop Subset User Manual
Page 4

Pub. 42004-429B
ICS Page/Party
®
Desktop Subset
Page 4 of 4
e:\standard ioms - current release\42004 instr. manuals\42004-429b.doc
11/13
Troubleshooting
The following table is provided to aid qualified service personnel in troubleshooting problems with the
ICS Page/Party
®
subset.
Problem Potential
Cause
Subset is not functional.
Verify DB25 Interconnect cable is properly terminated between
the subset and remote amplifier.
Refer to general troubleshooting section in ICS Page/Party
®
Remote Handset/Speaker Amplifier manual for adjustments and
settings that affect ICS subset operation.
Specifications
Handset
Microphone ...................................................................................................................................... Dynamic
Receiver .................................................................................................... Dynamic, hearing aid compatible
Cord ...................................................................................................... Retractile, 6-foot extended, Hytrel
®
Material ................................................................................................................................................... ABS
External control .............................................................................................. Push-to-page handset pressbar
Subset Specifications
Construction/finish .............................................. Black ABS Cycolac
®
housing with aluminum front panel
Mounting .................................................. Desktop or wall mount; two 0.20-inch (5.1 mm) mounting holes
Overall dimensions ..................................... 8.94 H
7.60 W 4.56 D inches (227.1 193.0 115.8 mm)
Shipping weight .................................................................................................................... 5.0 lbs. (2.3 kg)
Net weight ............................................................................................................................. 3.0 lbs. (1.4 kg)
Environmental
Temperature range (operation and storage) ............................................ −22º F to 158º F (−30º C to 70º C)
Humidity ...................................................................................................................... 95% non-condensing
Approvals
NRTL certified for use in US and Canada ............................................................................. UL/CSA 60950
CE Mark