3xe d – GAI-Tronics VoIP Telephone Software Configuration Guide User Manual
Page 59

GAI-TRONICS
VoIP Telephone Configuration Guide
Page 59 of 88
Section Item
Identifier
Value(s) Comments
DIALPLAN
MEMORY
[1-20] URI> This command sets the dial plan memory storage Examples: MEMORY=3 0015551234 COMFORT [1-20] This command is used to set a dial string to be used . Example COMFORT=8 1234567890 LIST [1-10] A B C D up to 20 entries This command sets the dial plan list associated with a OFFHOOK XX This command sets the memory list that is associated TERMINATOR [*|#] This command sets the dial string terminator MAXLEN XX This command sets the maximum dial string length to DIALTIME X This command sets the inter-digit timeout value to be CALLLIMIT X This command sets the maximum time allowed for a PRECALL X This command sets length of time in seconds that a CALLFAIL X This command set the length of time that the phone WAKEANDDIAL [0-10] [ON/OFF] Turns ON or OFF the wake and dial functionality for FAILOVERCAUSES Lists the Q.931 alike cause codes that cause the REMOTEALERTINGTIM EOUT [0-600] sets the maximum length of time in seconds that the LOCALALERTINGTIME OUT [0-600] sets the maximum length of time in seconds that the REMOTEALERTINGTIM EOUTCAUSECODE XX sets the cause code (from the table above) that will 3XE D
position to be the telephone number or SIP URI
specified in the value field. The entry can be cleared
by omitting the value.
MEMORY=13 [email protected]
to generate DTMF digits as a memory dial feedback
to the user. 30 Characters maximum length
memory or emergency key function to contain the
memory locations specified by A B C D and so on.
The order of call attempts will be as specified.
with the off hook state. Omitting the value parameter
sets the list to be non applicable and entering the off
hook state will not cause a memory /emergency list to
be applied. The default value is blank (non
applicable)
character to be either #, * or not used (if omitted ).
The default value is blank (not used). If the user dials
the selected character the call setup will be initiated.
XX digits. Once the user has dialled XX digits the call
will be initiated. The default value is 25 digits
X seconds. Once the user has entered the off hook
state, then failure to receive another digit within the
timeout period will result in the call being initiated with
the dialled digits received so far. A value of 0 seconds
disables the use of the inter-digit timeout. The default
value is 5 seconds.
call in minutes. The value of X can 0 – 240. The value
0 disables the timer. The default value is 0.
phone will remain in the initial off hook state
generating dial tone without a dialling key being
pressed. After this delay the phone will cease dial
tone and enter the on hook state even if the hook
switch is off hook. The value 0 disables this timeout.
The default value is 30.
will remain in the off hook state after the call has
ended. The default value is 30. A value of 0 disables
this timeout.
the associated memory LIST.
phone to fail over to the next entry in a dial LIST. The
default list is
FAILOVERCAUSES=1,1718,,21,27,38,41,50,88
phone will ring on an outgoing call before timing out
and returning "Number Unobtainable" (Tone 6) to the
user. A value of 0 disables the timer, meaning it will
ring until the caller hangs up or the remote end
refuses the call. Default value 0.
phone will ring on an incoming call before timing out
and returning a "no answer" result to the caller. A
value of 0 disables the timer, meaning it will ring until
the caller stops ringing. Default value 0.
be entered in the call description record (CDR) if an
outgoing call times out without being answered.
Default value 18.