Specifications

Electrical

Power requirements ............................................................................... 9.5 to 14 V dc (12 V dc nominal)

Current draw .............................................................................................. 300 mA maximum @ 12 V dc

Number of amplifier inputs.................................................................. 6-single channel or 3-dual channel

Fault input terminal voltage (Wet mode)........................................................................ 12 V dc (nominal)

Fault input voltage range (Wet mode) ............................................10–15 V dc (active); <8 V dc (inactive)

Fault input circuit current (Wet mode) ............................................................................................1.2 mA

Number of fault output contacts................................... 6 (single-channel mode) or 3 (dual-channel mode)

Fault output contact type ................................................................................................ Single Form “C”

Fault output contact rating ................................................................................. 2 A maximum @ 30 V dc

Amplifier Audio Switching

Amplifier type ........................................................................................................ Single or dual-channel

Audio input levels (typical per circuit) ................................ 600 ohm @ 0.775 Vrms (0 dBm) to 1.5 Vrms

Amplifier output power (maximum per circuit)............................................. 700 watts (100% duty cycle)

Speaker load switching.................................................................................. Standard 4, 8 or 16-ohms, or

25 V, 70 V or 100 V constant voltage lines

Terminations

Type..................................................................................................... Modular (plug-in) terminal blocks

Minimum conductor size ...................................................................................... No. 28 AWG (0.5 mm

2

)

Maximum conductor size...................................................................................... No. 12 AWG (3.0 mm

2

)

Mechanical

Module dimensions .................................... 12.00 L

× 4.00 W × 1.25 H inches (304.8 × 101.6 × 31.7 mm)

Module weight ................................................................................................................. 1.1 lbs. (0.5 kg)
Environmental

Temperature range (operating/storage)...................................................... 32

° F to 140° F (0° C to 60° C)

Humidity........................................................................................85% relative non-condensing humidity