GAI-Tronics 293-101 Externally Powered ADA-Compliant Emergency Phones User Manual
Page 24

Pub. 42004-378C
E
XTERNALLY
P
OWERED
ADA-C
OMPLIANT
E
MERGENCY
P
HONES
P
AGE
23
of 28
\\s_eng\gtcproddocs\standard ioms - current release\42004 instr. manuals\42004-378c.doc
08/06
Hardware Settings Table
Default Settings
User Settings
Function Setting
Jumper/Position
Setting
Jumper/Position
Auto-answer Enabled
J14/3
&
2
Password Protection
Enabled
J9/3 & 2
Line Polarity
Non-polarized
J6/3 & 2
Programming Table
Function Key
Sequence
Default
Settings
User Settings
Auto-dial Programming
Emergency Button Auto-dial Number 1
DD*1 *123456789*0#
Emergency Button Auto-dial Number 2
DD*2
None
Emergency Button Auto-dial Number 3
DD*3
None
Call Button Auto-dial Number
DD*4 None
Primary Dial Tone Delay
#10NN Infinite
Secondary Line Dial Tone Delay
#11NN
0 (zero) seconds
Ring-down Operation
*1
None
Password Programming
Password Protection
#14NNNN 2468
Disconnect Programming
Emergency Push-button Disconnect
#17L 01
(enabled)
Call Time-out Disconnect
#12NN 10
minutes
Dial Tone Disconnect
#19L 0
(disabled)
Other Programming Features
Silent Monitoring
#16L 0
(disabled)
Ringing #22L 0
(disabled)
ADA Programming
ADA Options Enable
#18L #181
Identification Code Entry
#13LNNN None
Table Key
D = digit 0-9, *, or #
N = digit 0-9
L = 0-Disable, 1-Enable
T = 0-350 ms, 1-50 ms, 2-25 ms