Maintenance
CAUTION
These servicing instructions are for use by qualified service personnel only.
To reduce risk of electric shock, do not perform any servicing other than that contained in the
operating section unless you are qualified to do so.
Regular inspection and a good preventive maintenance program will increase the reliability of your
GAI-Tronics station. The GAI-Tronics Field Service Department can formulate a service contract suited
to your facility’s specific need for preventive maintenance.
WARNING
Before performing any of the following preventive maintenance steps, remove
all power from the station.
CAUTION
To reduce the risk of ignition of hazardous atmospheres, disconnect the equipment from the supply
circuit before making any adjustments to the PCBA’s settings.
F1/F2 Fuses
WARNING
Do not remove fuses when energized. Replace with the same type
and size fuse for continued safe operation.
F1 is the fuse on the ac power line: 0.5A, SLO-BLO, 250V, 5
20mm, UL.
F2 is the fuse on the dc power line: 2.0A, SLO-BLO, 250V, 5
20mm, UL.
Inspect and clean the machined flange flame joint surfaces of both the cover and box. Surfaces must be
smooth, free of nicks, scratches, dirt or any foreign particle build-up that would prevent a proper seal.
Surfaces must seat fully against each other to provide a proper explosion-proof joint. Clean surfaces by
wiping with a clean lint-free cloth.
Install and tighten all cover bolts to 17 ft-lbs, (23 N-m). Make certain no cover bolts are omitted. Use
only those bolts supplied with the enclosure.
Troubleshooting
Problem
Solution
Any problem with station
performance
Always review all steps of installation, ensuring that you
correctly followed all steps. Check all terminations on the
board.
Speaker volume needs
adjustment
Adjust volume control.
Replace speaker or driver.
Crosstalk
One or more system cable pairs may be improperly terminated.
Visually inspect the system cable for accidental crossing of
cable pairs or grounds.