This section includes two troubleshooting charts designed to quickly pinpoint the source of problems.
Troubleshooting
N
OTE
: It may be advantageous to temporarily connect a Model 262-001 or 272-001 Telephone panel
directly to the output terminals of the Model 263-000 IBU when troubleshooting. Then, using the charts
below, the cause of the problem should more easily be determined.
Non-Equipment Related Problems
Problem Solution
The I.S. telephone is inactive
with no lights on the IBU when
the telephone is off-hook.
1. Check the ac power to the Model 263-000 IBU.
2. Check the ac fuse F4 at the Model 263-000 IBU.
3. Ensure there is no wiring open at the I.S. telephone.
The I.S. telephone has no dial
tone.
1. If the I.S. telephone has a wiring short, the IBU lights will be lit
in the following pattern:
=
On
,
= Off
ISLOOP
LOCK
HOOK
TELCO
2. If the TELCO line has an open, the IBU lights will be lit in the
following pattern:
=
On
,
= Off
ISLOOP
LOCK
HOOK
TELCO
The lights on the IBU flash
randomly.
The I.S. telephone has an intermittent wiring short. The short may be
between the conductors or either/both conductor(s) to ground/shield.