beautypg.com

Installing the model 272-001 outdoor telephone, System setup – GAI-Tronics 262-001 Intrinsically-Safe Telephones User Manual

Page 4

background image

Pub. 42004-173G

Model 262-001 and 272-001 Intrinsically-Safe Telephones

Page 4 of 12

f:\standard ioms - current release\42004 instr. manuals\42004-173g.doc
08/14

Installing the Model 272-001 Outdoor Telephone

The Model 272-001 Outdoor Telephone is intrinsically safe when connected in accordance with GAI-
Tronics drawing 73242 (Pub. 42004-380).

1. Open the front door of the enclosure and locate the four outermost screws.

2. Loosen these four screws, and carefully pull the enclosure apart until there is a slight resistance on the

left side of the enclosure.

3. Separate the front half of the enclosure from the rear half by pulling on the left side of the enclosure

until the hinge plugs pull loose.

4. Put the front half of the enclosure aside, and mount the enclosure to the wall using four ¼-inch screws

of the appropriate length, depending on the mounting surface.

5. Feed the station wire through the hub at the bottom of the enclosure.

6. Refer to drawing 73242 (Pub. 42004-380) for wiring details. The station wire is the pair of wires

coming directly from the GAI-Tronics Model 263-000 Isolation Barrier Unit. This unit must not be
connected directly to the telephone system.

7. Close the front half of the enclosure, and secure it by tightening the four outermost screws.

WARNING

Substitution of components may impair intrinsic safety.

System Setup

GAI-Tronics recommends taking the following steps to ensure a safe and trouble-free installation:

1. Install the Model 263-000 Isolation Barrier Unit (IBU) and wire it completely, except for the

hazardous area signal wires.

WARNING

The unit must be wired in accordance with

drawing 73242 (Pub. 42004-380) to ensure intrinsic safety.

2. Next, temporarily connect the I.S. telephone to the IBU with a short pair of conductors, and operate

the unit by making a test telephone call. If any problems are detected, see the Troubleshooting
section.

3. Call the I.S. telephone from another telephone, and adjust the

RING PITCH

(located on the IBU) to

the desired pitch.

4. Disconnect the I.S. telephone and install it in the intended permanent location.

WARNING

The unit must be wired in accordance with

drawing 73242 (Pub. 42004-380) to ensure intrinsic safety.

5. Make a call from the I.S. telephone. If any problems are detected, see the Troubleshooting section.

This manual is related to the following products: