SPC-20 SPECIFICATIONS
AC INPUT
120VAC, 60 Hz, 20Amps max.
AC INPUT:
Full line conditioning and RFI suppression
AC SWITCHING:
Solid state zero crossing (no relays that bounce,
arc,
and
pit)
AC OUTLETS:
Surge suppression on all outlets
AC OUTLETS:
Total
of
fi ve outlets, two (one on the front panel
and one on the rear panel) are active, the other
three are switched on/off in sequence. Total out-
put current must not exceed 16 Amps. Each
AC outlet is rated at 16 Amps but remember
that the total current out of the SPC-20 must
not exceed 16 Amps.
SURGE PROTECTION: Spike protection modes: Line to neutral, neutral to
ground,line to ground Spike protection voltage:
Max clamping voltage 340V peak, L-N, N-G, L-G
Response time: 1 nanosecond
Maximum surge current: >100,000 AMPS (8x20
usec pulse)
Maximum spike energy: >1000 joules
Noise attenuation: Differential 13 dB @ 150 kHz
ncreasing to 45 dB @ 30 Mhz
Common mode: 15 dB @ 150 kHz, increasing to
>45 dB @ 30 Mhz
SWITCHING DELAY: 1 to 50 seconds adjustable on the rear panel. This is the delay
from circuit 1 to circuit 2. All subsequent delays will be one
to three seconds, dependent on the adjustment.
Example:
When the SPC-15 power is powered up, via either the front panel power switch or via
remote triggering and you have chosen to set the delay to 20 secs:
The SPC-15 “circuit 1” turns on within 1 sec.
Then, the SPC-15 “circuit 2” turns on in 20 secs.
Then, the SPC-15 “circuit 3” turns on in 22 secs.
Then, the fi rst SPC-15X expansion module turns on in 24 secs.
Then, the second SPC-15X expansion module turns on in 26 secs. and so on for
additional SPC-15X modules.
When the SPC-15 power is powered down, via either the front panel power switch or
via remote triggering, all delays happen in reverse:
The last SPC- 15X expansion module turns off fi rst. Additional SPC-15X expan-
sion modules will continue to turn off in sequence at 2 second intervals.
Then, 2 secs later, after all the SPC-15X expansion modules have sequenced off,
the SPC-15 “circuit 3” turns off
Then, 20 seconds later, the SPC-15 “circuit 2” turns off
Then, within one sec, “circuit 1” turns off
REMOTE CONNECTOR: Includes all connections for remote control of the unit (
pluggable screw terminal connector)
REMOTE CONTROL: Momentary or maintained closure will operate
this
equipment. A lamp feedback signal (voltage) is also provid-
ed.
EXPANSION CONNECTOR: Feeds the fi rst expansion unit if used data connector 6
wide RJ 12) wire this connector straight through.
NOTE: THIS IS NOT TO BE USED AS A TELECOM INPUT. DO NOT PLUG A
TELEPHONE INTO THIS CONNECTOR
SIZE:
19” wide, 1.75”high and 8.5” deep
WEIGHT:
14 lbs