9. INSTALL 1RU TO 4RU x 19" EIA RACK-SIZED ELECTRONICS.

MAKE ELECTRICAL CONNECTIONS AS REQUIRED. RACK
MOUNT BRACKETS CAN BE RE-POSITIONED TO ALTERNATE
HOLES, OR ADDITIONAL BRACKETS MAY BE PURCHASED
(CB-224RKRL).

NOTE: MAXIMUM LOAD INSIDE CARRIAGE - 25 LBS

a

7. PULL DOWN DROP-DOWN RACK-MOUNT CARRIAGE TO MOUNT

ELECTRONICS. (a) PUSH LOCK ARM AWAY FROM POLE MOUNT
AND (b) AND PULL DOWN ON CHAIN. ONCE THE DROP-DOWN
CARRIAGE IS PULLED FULLY DOWN (c) AGAIN PUSH THE LOCK
ARM AWAY FROM POLE MOUNT TO LOCK CARRIAGE IN THE
'DOWN' POSITION. REVERSE PROCEDURE TO RETRACT
CARRIAGE BACK INTO CEILING BOX.

NOTE: MAXIMUM LOAD INSIDE CARRIAGE - 25 LBS

MOUNTING ELECTRONICS INSTRUCTIONS

5. DETERMINE LOCATION OF POLE MOUNT FLANGE.

LOOSEN (4) #10-32 HEX SCREWS AND SLIDE POLE
MOUNT FLANGE TO NEW POSITION AND TIGHTEN HEX
SCREWS. IF INSTALLING FAN KIT PROCEED TO STEP
6. RE-INSTALL POLE MOUNT FLANGE COVER,
ADJUSTMENT BAR COVER AND CEILING BOX DOOR
BACK INTO CEILING BOX BY REVERSING THEIR
REMOVAL STEPS. PROCEED TO STEP 7.

6. REMOVE (4) #8-32 SCREWS AS SHOWN, AND EXTRACT POLE

ADJUSTMENT BAR. INSTALL FAN KIT PER INSTRUCTIONS. RE-INSTALL
POLE ADJUSTMENT BAR, POLE MOUNT FLANGE COVER, ADJUSTMENT
BAR COVER AND CEILING BOX DOOR BACK INTO CEILING BOX BY
REVERSING THEIR REMOVAL STEPS. PROCEED TO STEP 7.

NOTE: MAXIMUM PROJECTOR LOAD INCLUDING
MOUNTED ACCESSORIES - 50LBS

NOTE: THE CENTER OF MASS
OF SUSPENDED EQUIP-
MENT MUST BE WITHIN
A 2.5" RADIUS OF THE
CENTER LINE OF THE
POLE MOUNT FLANGE
OF THE CEILING BOX.

LOCK ARM

DROP-DOWN
RACK-MOUNT
CARRIAGE

c

b

PULL CHAIN

(4) RACK
MOUNT
BRACKET
INCLUDED

ALTERNATE
RACK MOUNT
BRACKET HOLES

ALTERNATE/ADDITIONAL
RACK MOUNT BRACKET
HOLES ON OPPOSITE
SIDE OF CARRIAGE

CAUTION: ONCE THE LAST SCREW IS REMOVED FROM THE POLE

ADJUSTMENT BAR, IT CAN FALL OUT. HOLD POLE
ADJUSTMENT BAR IN PLACE WHILE REMOVING SCREWS.

POLE ADJUSTMENT BAR

(4) #8-32 x 3/8"-LONG

FLAT HEAD SCREW

VIEW SHOWING

ALTERNATE

BRACKET

HOLES USED

POLE MOUNT FLANGE

(4) #10-32 x 3/4"-LONG

HEX SCREW

(2) #8-32 x 1/4-LONG

PAN HEAD SCREW

(2) WIRE
BUNDLE
INLET

(2) WIRE

INLET

FOAM

(2) WIRE

INLET

COVER

8. INSTALL WIRE BUNDLE INLET, WIRE

INLET FOAM, AND WIRE INLET COVER
TO SIDES OF BOX. REMOVE THE FOAM
BLOCKS NECESSARY FOR THE WIRE
BUNDLE EXITING THE BOX. PULL
WIRES TO CEILING BOX THRU WIRE
INLET OR CONDUIT AS REQUIRED.

FLANGE

ADJUSTMENT BAR COVER

POLE MOUNT FLANGE COVER

(2) #8-32 x 1/4"-LONG

PAN HEAD SCREW

4. REMOVE (2) #8-32 SCREWS AS SHOWN, AND REMOVE

ADJUSTMENT BAR COVER. SUPPORT ADJUSTMENT
BAR COVER WHILE REMOVING SCREWS. POLE
MOUNT FLANGE COVER IS NOT FASTENED AND JUST
SLIPS OUT.

REMOVABLE
FOAM BLOCKS

PART OF

POLE MOUNT

FLANGE

COVER

SCREWS LOCATED IN
INTERIOR OF CEILING BOX

INSTALLING OPTIONAL FAN KIT: