ML-116 INSTALLATION DATA

Membrane Wallplate Dip Switch Settings

The ML-116 allows for up to 32 wallplates: 2 per room up to 16 rooms. The wallplates must be
individually addressed. The addresses are set by setting the dip switches on the back of the wallplate.
The address is a binary code representing the room number minus one, given on switches 1 through
4 with a closure representing a 1.

.

Note: 0= switch open
1= switch closed

Switch 5 is used for rooms with two wallplates. In a two wallplate room, one and only one of the
wallplates (it does not matter which one) should have switch five closed.

Switches 6 through 8 are used for factory self tests and should be open for normal use.

1-5 ADDRESS
6-8 FACTORY USE ONLY