ML-116 INSTALLATION DATA
Membrane Wallplate Dip Switch Settings
The ML-116 allows for up to 32 wallplates: 2 per room up to 16 rooms. The wallplates must be
individually addressed. The addresses are set by setting the dip switches on the back of the wallplate.
The address is a binary code representing the room number minus one, given on switches 1 through
4 with a closure representing a 1.
.
Note: 0= switch open
1= switch closed
Switch 5 is used for rooms with two wallplates. In a two wallplate room, one and only one of the
wallplates (it does not matter which one) should have switch five closed.
Switches 6 through 8 are used for factory self tests and should be open for normal use.
1-5 ADDRESS
6-8 FACTORY USE ONLY
Picture of rear of wallplate
S W I T C H
1
2
3
4
S W I T C H
1
2
3
4
ROOM 1
0
0
0
0 ROOM 9
0
0
0
1
ROOM 2
1
0
0
0 ROOM 10 1
0
0
1
ROOM 3
0
1
0
0 ROOM 11 0
1
0
1
ROOM 4
1
1
0
0 ROOM 12 1
1
0
1
ROOM 5
0
0
1
0 ROOM 13 0
0
1
1
ROOM 6
1
0
1
0 ROOM 14 1
0
1
1
ROOM 7
0
1
1
0 ROOM 15 0
1
1
1
ROOM 8
1
1
1
0 ROOM 16 1
1
1
1
SWITCH POSITIONS