Dip switch / jumper settings – FSR ML-116 User Manual
Page 23

FSR
ML-116 INSTALLATION DATA
Telephone 973-785-4347
page 23
DIP SWITCH / JUMPER SETTINGS
ACU Audio Control Unit, CPU Module
The CPU Module contains sixteen (16) dip switches which will allow users to customize the system to
a large degree. These switches in addition to two jumpers on each room audio (RA) module, allow the
user to select such options as simultaneous microphone and music operation, key switch interlock
functions, ramp speed, etc. The definition of the switches are as follows:
Dip switch
Factory Setting
Explanation
1
open
Memory Volume
2
open
Preset Volume
3
open
Reserved
4
open
Enable Mode
5
open
[Wall Plate
6
open
Interlock Mode]
7
open
Reserved
8 closed Cold Start Select
9
open
Select multiple Systems
10
open
Select multiple Systems
11
open
Select multiple Systems
12
open
Select multiple Systems
13
open
Reserved
14
open
If Monitor Panel Present
15
open
If FMP present
16
open
If Map Panel Present
Dip switch 1 - Initial Volume Memory Option - closed the volume is determined by the dipswitch
2 setting, if open the volume is restored to level that was last set.
Dip switch 2 - Preset Volume - Setting determines the power up default volume level, if closed
the volume initializes to -12 db, if open it initializes to 0 db.
Dip switch 3 - Reserved
Dip switch 4 - This dip switch allows simultaneous operation of voice and music. If the dip
switch is open then the system is in normal mode, the voice and music are exclusive. This is com-
monly referred to as the pre-enable mode. If the dip switch is closed, both voice and music can be
operated at the same time (simultaneous mode). The system is shipped with this dip switch in the
open position.