beautypg.com

Dip switch / jumper settings – FSR ML-116 User Manual

Page 23

background image

FSR

ML-116 INSTALLATION DATA

Telephone 973-785-4347

page 23

DIP SWITCH / JUMPER SETTINGS

ACU Audio Control Unit, CPU Module

The CPU Module contains sixteen (16) dip switches which will allow users to customize the system to

a large degree. These switches in addition to two jumpers on each room audio (RA) module, allow the

user to select such options as simultaneous microphone and music operation, key switch interlock

functions, ramp speed, etc. The definition of the switches are as follows:

Dip switch

Factory Setting

Explanation

1

open

Memory Volume

2

open

Preset Volume

3

open

Reserved

4

open

Enable Mode

5

open

[Wall Plate

6

open

Interlock Mode]

7

open

Reserved

8 closed Cold Start Select

9

open

Select multiple Systems

10

open

Select multiple Systems

11

open

Select multiple Systems

12

open

Select multiple Systems

13

open

Reserved

14

open

If Monitor Panel Present

15

open

If FMP present

16

open

If Map Panel Present

Dip switch 1 - Initial Volume Memory Option - closed the volume is determined by the dipswitch

2 setting, if open the volume is restored to level that was last set.

Dip switch 2 - Preset Volume - Setting determines the power up default volume level, if closed

the volume initializes to -12 db, if open it initializes to 0 db.

Dip switch 3 - Reserved

Dip switch 4 - This dip switch allows simultaneous operation of voice and music. If the dip

switch is open then the system is in normal mode, the voice and music are exclusive. This is com-

monly referred to as the pre-enable mode. If the dip switch is closed, both voice and music can be

operated at the same time (simultaneous mode). The system is shipped with this dip switch in the

open position.