beautypg.com

FSR ML-116 User Manual

Page 17

background image

FSR

ML-116 INSTALLATION DATA

Telephone 973-785-4347

page 17

Wall Plates

Size:

6 1/4 inches wide by 4 1/2 inches high, approximately 2.5 inches deep

Mounting:

fits standard 2 or 3 gang electrical wall box with four or 6 screws

Switches:

membrane

Connector:

5 pin connector

Cable:

West Penn #3651 or 3751 (see page 13 for details)

Power Supply (PSA)

Size:

3 1/2 inch high, 6 inches deep, 10 inches long (approximately)

Mounting:

rear rack rail

Input power: 105 to 132 VAC, 50/60 Hz, 100 watts
Output:

+15 volts, +25 volts, -25 volts nominal

Fuse:

2 amp

Switch:

power on/off (lighted rocker switch)

Interconnect: 8 foot cable supplied, 5 conductor stranded
Indicators:

three LED indicators, one for each of the unregulated voltages

MON Monitor/VU Panel Assembly (optional)

Monitor/VU Panel

Input:

70Volt speaker level

Size:

19 inches wide, 5 1/4 inches high(3RU), 4 1/2 inches deep overall

Mounting:

standard rack rails

Monitor Relay Card (supplied with the Monitor/VU card)

Size:

3 1/4 inches wide, 9 1/2 inches long, 1 inch high, comes already mounted in a

19 inch FSR TRAC-BRAC

Mounting:

rear rack rails

MLH Head Table Speaker Assembly (optional)

Head Table Breakout Card (HTBC)

Size:

3 1/4 inches wide, 2 3/4 inches long, 1/2 inch high

Power:

HT-PS supply provided

Head Table Relay Card (HT-8)

Size:

3 1/4 inches wide, 7 1/4 inches long, 1 inch high, can have up to four of these

cards per system

Mounting:

rear rack rails, both the HTBC and the HT card come already mounted in a 19

inch FSR TRAC-BRAC

FM Facility Manager Control (optional)

Facility Managers Panel (FM-INT)

Size:

an enclosed box 3 1/2 inches wide, 5 inches long, 1 1/2 inches high

Mounting:

sits on the managers desk

Power:

a wall mounted power supply