Fluke Biomedical 945A User Manual
Page 51

MC6802 • MC6808 • MC6802NS
Bus Timing Characteristics
Ident.
Characteristics
Symbol
MC6802NS
MC68A02 MC68B02 UNIT
Number
MC6802
MC68A08
MC68B08
MC6808
Min Max Min Max Min Max
1
Cycle
Time
tcyc 1.0 10 0.667
10 0.5 10 µs
2
Pulse Width, E Low
PWEL 450 5000 280 5000 210 5000 ns
3
Pulse Width, E High
PWEH 450 9500 280 9700 220 9700 ns
4
Clock Rise and Fall Time
tr, tf
- - -
25
- - -
25
- - -
20
ns
9
Address Hold Time
tAH
20
- - -
20
- - -
20
- - -
ns
12
Non-Muxed Address Valid Time
tAV1
160
- - -
100
- - -
50
- - -
ns
to E (See Note 5)
tAV2
- - -
270
- - -
- - -
- - -
- - -
ns
17
Read Data Setup Time
tDSR
100
- - -
70
- - -
60
- - -
ns
18
Read Data Hold Time
tDHR
10
- - -
10
- - -
10
- - -
ns
19
Write Data Delay Time
tDDW
- - -
225
- - -
170
- - -
160
ns
21
Write Data Hold Time
tDHW
30
- - -
20
- - -
20
- - -
ns
29
Usable Access Time
tACC
605
- - -
310
- - -
235
- - -
ns
(See Note 4)
1
2
3
4
4
10
12
4
9
18
18
29
19
NOTE 4
MPU Read Data Non-Muxed
4
9
18
21
E
Read Data
(Non-Muxed)
R/W, Address
(Non-Muxed)
Write Data
Non-Muxed
17
NOTES:
1.
Voltage levels shown are VL < 0.4 V, VH > 2.4 V, unless otherwise specified.
2.
Measurement points shown are 0.8 V and 2.0 V, unless otherwise noted.
3.
All electricals shown for the MC6802 apply to the MC6802NS and MC6808, unless otherwise noted.
4.
Usable access time is computed by: 12 + 3 + 4 - 17.
5.
If programs are not executed from on-board RAM, TAV1 applies. If programs are to be stored and executed from on-
board RAM, TAV2 applies. For normal data storage in the on-board RAM, this extended delay does not apply.
Programs cannot be executed from on-board RAM when using A and B parts ( MC68A02, MC68A08, MC68B02,
MC68B08). On-board RAM can be used for data storage with all parts.
Figure 4-3. Read / Write Timing Diagram
4-27