beautypg.com

Filter change, pulsair iii w and z, Converting for remote control – Flowserve Pulsair III Digital User Manual

Page 27

background image

52

Worcester Controls Pulsair III Digital Electronic Positioner FCD WCAIM2056-00 - 08/04

fl owserve.com

53

Worcester Controls Pulsair III Digital Electronic Positioner FCD WCAIM2056-00 - 08/04

Filter Change, Pulsair III W and Z

a

Warning: Turn off the compressed air supply before starting any work. Oth-

erwise the fi lter can be uncontrollably blown out of the positioner by the air

pressure, which can be dangerous.

• Remove the fi lter cap using a coin of suitable size.

Note: Do not use a screwdriver. The fi lter cap might crack and cause air leakage.

Converting for Remote Control

a

Warning: Disconnect or switch off the power supply before starting any work.

1. Remove cover and inner cover, see instructions earlier in this section.

2. Lift off the display pcb, D.

D

3. Disconnect and secure the potentiometer cable.

4. Install transmitter board D3-AS38T, F.

F

G

5. Install the enclosed wire between G and O.

6. Connect the wiring betwen terminals 3, 4, 5 in the W unit and 3, 4, 5 in the remote

unit.

Use a shielded wire and ground it in the W unit only.

Avoid distances more than 16 ft. (5 m) between W unit and remote unit.

34

5

3 4 5

O