Front panel remote control serial port (remote), General purpose control input port (gpi/o in), 7 front panel remote control serial port (remote) – Dolby Laboratories DP569 User Manual
Page 56: 8 general purpose control input port (gpi/o in)
Model DP569 User’s Manual
Specifications
6-4
6.2.7
Front Panel Remote Control Serial Port (Remote)
8-pin female mini-DIN connector, electrical specifications per EIA RS-232
Table 6-4 Front Panel Remote Control Serial Port Pin-Outs
Pin
Connection
1 NC
2 NC
3
RX asynchronous data out
4 Ground
5
TX asynchronous data in
6 NC
7 NC
8
Sense select front panel
6.2.8
General Purpose Control Input Port (GPI/O In)
9-pin female D-connector, 5 V CMOS input levels (active low)
Table 6-5 General Purpose Control Input Port Pin-Outs
Pin
Connection
Comments
1
Bypass
Select Ref input as source for Switched output.
2
Autodetect
Autodetect and pass-through valid AC-3 signals.
3
Pre-encoded
Force Pass-through mode (no AC-3 encoding).
4
PCM
Force AC-3 encoding (no pass-through mode).
5
User Preset 1
Select user preset mode 1.
6
User Preset 2
Select user preset mode 2.
7
User Preset 3
Select user preset mode 3.
8
User Preset 4
Select user preset mode 4.
9
Ground --