Flowserve ValveSight Diagnostics User Manual
Page 51
![background image](https://www.manualsdir.com/files/784840/content/doc051.png)
ValveSight Diagnostics for HART User Manual FCD VSENSF0001-02-AQ 03/15
51
flowserve.com
The default button at the top of the graph will load the default custom curve. Rangeability curves can be automatically
generated by adjusting the Inherent Rangeability value (default 30) and selecting the graphing icon next to it. Select
Apply
to make the curve active. Select the
Reset button to return to the custom curve currently stored in the positioner.
Save and Load curves that you customize by using the corresponding buttons at the bottom of your screen. Retrieve will
display the custom curve currently stored in the positioner.
12.6 Units
Units of measure change the display and calculation of values on other DTM screens. The units for the electronics hous-
ing Temperature and the actuator Pressures can be set for the Logix MD positioner here. Position is always displayed in
0-100% of travel.
Units
The Units box has an Electronics Housing Temperature UOM and an Actuator Pressure UOM fields with the following options:
• Electronics Housing Temperature UOM - Celsius or Fahrenheit
• Actuator Pressure UOM - Lbs/in@ (psi), 100 kPa (bar), Kg/cm2, KiloPascals (kPa), or Percent (%)
Select
Apply to save the selections to the positioner. Retrieve can be used to view values currently stored in the positioner.