View Signals vs. Command

The

View Signals vs. Command button sets the graph to show the command on the X axis with the corresponding signals. If

a bi-directional signature has been taken, it shows both the sets of signals relative to the command.

View Friction/Thrust

The

View Friction/Thrust button calculates the friction in the valve based on the pressures measured during the signature

test. This friction is independent of the friction calculation which is shown in the Valve Health screen.

Data Management

At the bottom of the screen there are buttons to manage the signature data. You can

Save the data to a file, or Load

(retrieve) a previously stored signature from a file for viewing.

7.2 Step Test

Step Tests are a powerful tool for bench testing valves in a shop or installed valves that are not in service and can be fully
or partially stroked. By stepping the valve with a known step size and monitoring the response, you can note changes
over time and pinpoint problems that are developing or existing.