Limitorque Worcester Controls CEA Series FCD WCENIM2080-00-AQ 12/14
flowserve.com
Performance Specifications
Actuator
Output
Torque
(Continuous
Start/Run
Torque)
Stall
Torque
(1.25X)
Cycle Time
(90°)
24VDC
120/240VAC
Output
Speed
24VDC
120/240VAC
Full Load Amps
Version
Platform
(PF)
Model
Units
Nm (in-lbs)
Nm (in-lbs)
Sec.
RPM
24VDC
120/VAC
240VAC
Standard
On/Off
Modulating
PF1
M15
17 (150)
21 (187)
5
3
0.8A
0.15A
0.08A
M60
68 (600)
85 (750
5
3
2.1A
1.0A
0.49A
M150
169 (1500)
211 (1875)
10
1.5
4.2A
1.4A
0.75A
PF2
M250
282 (2500)
422 (3125)
16
0.9
6.5A
1.6A
0.85A
M500
565 (5000)
706 (6250)
33
0.5
6.5A
1.6A
0.85A
Materials of Construction
Component
Material
Housing and Cover
Die cast aluminum
Aluminum surface treatment
Non-chrome conversion coating
Worm Gear set
Ductile iron (M15, M60), Bronze (M150, M250, M500)
Output Drive
Ductile iron
Baseplate
ISO 5211, F05/07, FA05/07
Paint
Polyester powder coat
Salt Spray: ASTM B117, 1050 hrs.
Technical Data
Voltage Rating
120/240 VAC/VDC; 12*/24 VDC; Single (and optional 3-phase)
Temperature
-40C to +70C, low temp. option -48C
Environmental
Type 4, 4X,6, IP66/68 (3m for 48hrs)
Class 1, Div 1,2, Gps B,C,D (CSA,FM)
ATEX II 2G Ex d IIB +H2 T4: IECEx II 2G Ex d IIB +H2 T4
Vibration Testing
IEC60068-2-6 Appendix B
CE Declaration
Low voltage, EMI/EMC approval
Weight
M15/60: 24 lbs (10.9kgs) M150: 25.5 lbs (11.6kgs)
* For 12VDC, consult factory