background image

DS_S24SA1R812_05092006

ELECTRICAL CHARACTERISTICS CURVES



Strip

Copper

Vo(-)

Vo(+)

10u

1u

SCOPE

RESISTIVE

LOAD

Figure 9

:

Input Reflected Ripple Current, is, at full rated output

current and nominal input voltage with 12

µ

H source impedance

and 100

µ

F electrolytic capacitor (2 mA/div).

Figure

10:

Output voltage noise and ripple measurement test

setup. Scope measurement should be made using a BNC
cable (length shorter than 20 inches). Position the load
between 51 mm to 76 mm (2 inches to 3 inches) from the
module.

0.0

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

0.0

5.0

10.0

15.0

20.0

LOAD CURRENT (A)

OUTPUT VOL

T

AGE (V)

Vin=24V

Figure 11:

Output voltage ripple at nominal input voltage and

rated load current (10 mV/div). Load capacitance: 1

µ

F ceramic

capacitor and 10

µ

F tantalum capacitor. Bandwidth: 20 MHz.

Figure 12:

Output voltage vs. load current showing typical

current limit curves and converter shutdown points.