Rear Panel Connections

9

REAR PANEL CONNECTIONS

R1, RF OUTPUT

--- This type "F" connector is the high level (+45 to +61 dBmV), 54 to 1002 MHz, output from the EH24A

RF output section.

R2, VIDEO 1 & 2

- These two RCA type connectors color coded yellow provide two separate video inputs to the

SDE24/SDE24A Encoder.

R3, AUDIO 1 & 2

- These four color coded RCA type connectors provide audio Left (white) and Right (red) inputs

to the SDE24/SDE24A Encoder.

R4,

This is space available for additional SDE24/SDE24A Encoders which may be installed in the EH24A Encoder Host.

R5, ASI OUTPUT

- This BNC type connector provides ASI output of the multiplexed transport streams from selected

encoders.

R6,

Cooling Air Vents

R7, Ethernet Port

- Connection to a PC or modem for use with remote control / monitoring program or for firmware

upload.

R8, AC Line Cord Socket

--- For connection to the mains AC power source. The removable line cord allows for operation

in various countries. Use an appropriate cord for your needs that has been recognized by a certified safety agency. This unit

is usually supplied with a cord for USA operation on 120 VAC.

The power supply automatically accepts a mains supply from 90 to 264 VAC, 47 to 63 Hz. Power consumption will vary

depending on the number of modules installed but worst case consumption is 70 W.

R9, EAS

- This terminal is used to supply the EH24A with a contact closure when the EAS is activated, as determined by

an external EAS controller/receiver. The external EAS controller will supply a contact closure output for connection to the

EH24A EAS and GND terminals. Grounding the EAS screw terminal, through the contact closure in the controller, will signal

the EH24A that an EAS event has occurred. If EAS has been programmed and the EAS encoder installed, the EH24A will