Pbio register mapping to shotlist location, Trigger – DNF Controls 2034CL-L-PBIO VS.3.0 User Manual
Page 12

12
2034CL-L, Vs.3.0, 300 Clip Instant Access System, Louth Protocol, PBIO
Option
9.
PBIO REGISTER MAPPING TO SHOTLIST
LOCATION
Register 0-30 Î
Cue Point 0-30
Register 31-60 Î Cue
Point
101-130
Register 61-90 Î Cue
Point
201-230
Register 91-99 Î Cue
Point
301-309
10. TRIGGER
The operator fires a trigger using the Timeline or Run function on the production switcher. The
ST300 puts the Video Server into the following modes based on the trigger value:
GRASS VALLEY GROUP
Trigger
Value
Mode
0
Play
1
Recue to beginning of clip
2
Slo-mo
using
ST300
Preset
Speed
3
Reverse
Play
4
Still
Frame
5
Play
6
Record
7 or greater
Play
SONY
Trigger
Value
Mode
0
Recue to beginning of clipPlay
1
Play
2
Slo-mo
using
ST300
Preset
Speed
3
Reverse
Play
4
Still
Frame
5
Play
6
Record
7 or greater
Play
To control more than one VTR, enable the Peripheral Device Address for the required VTRs. The
Trigger will be sent to the enabled devices.
OR
GANG the required VTRs on the ST300. See the Menu Table for GANG instructions. Enable the
Peripheral Device Address for one of the GANGed VTRs. The Trigger will be sent to the enabled
VTR. The other VTRs in the GANG will perform the same action.